POT-1

Pull-off type opening force tester

Features :

- Range: 50 / 200 / 1000 N (To be specified when ordering)

- Measurement in tension and compression

- Reversible Digital Display

- Menu-based programming.

- Continuous / Peak / PC connection measurement modes

- Zero recalibration

- Accuracy: 0.05 N (depending on the range)

- Display and programming of thresholds

- Units: kgf / Lbf / N

- Built-in battery

- Data transfer and curve

- Dimensions: 500 x 250 x 600 mm

- Weight: 15 kg

- Air intake: 0 - 6 bar

Options:

Use :

- Install the hook in the ring of the capsule and the wire in the lower pulley.

- Operate the pneumatic valve using the handle to perform the first "stretching" step. This step should be carried out at a constant speed for more accurate measurement.

- Change the wire towards the upper pulley (this position is set at 45° but can be changed)

- Reactivate the pneumatic valve using the handle to perform the second "stretch 2". This step should be carried out at a constant speed for more accurate measurement.

- Return the handle to the initial position to complete the test.

Description :

POT-1 was developed to allow testing on “pull off” capsules while respecting each step.

The POT-1 incorporates a precision dynamometer and semi-automatic cycles for improved test reproducibility. The angle of each step is adjustable. This device was developed to allow testing on various bottle sizes.